Kami menjual dan memproduksi Alat Kualitas Udara dengan harga murah serta kualitas terbaik.
Untuk informasi lebih lanjut dapat menghubungi

Rabu, 29 November 2017

Lux Meter

Lux Meter


Measuring range:0-50000LUX 0-5000FC
3 RANGE: x1,x10,x100
resolution: 1
Accuracy: ±5%n
HOLD
Band pass filter
Overload indication: 1
Power supply: 4x1.5V AAA (UM-4) battery
Battery indicator: low battery indicator
Dimensions: 97x53x17mm

Lux Meter

Lux Meter


Range : Lux, 40, 400, 4,000, 40,000, 400,000
Foot candle : 40, 400, 4,000, 40,000.
Resolution : 0.01.
Basic accuracy : ±3% rdg + 5 digits.
Dimensions : 5.9” x 2.8” x 1.4”

Solarimeter Kimo

Solarimeter Kimo


Solar irrigation measuring range : 1 W/ m2 to 1300 W/ m2
Energetic exposure measuring range : 1 Wh/ m2 to 500 kWh/ m2
Frequency of the measure : 2 / s
Accuracy : 5% of measurement
Calculation frequency ( W/ m2) : 1 / min ( average on 60 seconds)
Storage capacity : 31 days, 44640 saved recording points
Fast datas download : 1000 values/ second
Detection : out of range and sensor default
Operating temperature : from -10° C to + 50° C
Storage temperature : from -10° C to + 55° C
Package dimensions : 58 x 120 x 33 mm
Autonomy : more than 72 hours in continuous mode
Unlimited with power supply adapter
Power supply : 3 LR3-AAA batteries
Electronic : Digital
E lectronic card : Varnish
Conformity : in accordance with RoHS directives

Gauss Meter

Gauss Meter


Gauss Meter
Range (ST Probe): Up to 30,000 Gauss /1G indicates polarity
Range/Resolution (HS Probe): 0 to799.99 Gauss / 0.01G indicates polarity
Accuracy (w/ probe) 16° to 29°C: 1% of DC reading / 3% AC +/- 10 Counts / 1% peak hold
Accuracy (w/ probe) -4° to 65°C: 2% of DC reading / 4% AC +/- 10 Counts / 2% peak hold
AC Frequency Range: 45-800 Hz; 3 dB limits are 11 to 1500 Hz.
Peak Hold Speed: 2 millisec pulse is 71%, 5+ millisec pulse is 100%±1%
Output Type: Analog DC Signal.
Output Magnitude (ST Probe): Below 20kG, output is 0.1mV/G. Above 20kG, it is 0.01 mV/G
Output Magnitude (HS Probe): 1mV/G
Meter Size: 138 x 91 x 41 mm
Weight: 7.5 Oz
Battery: 9 volt alkaline (~40 hour life with ST probe, ~ 20 with HS probe); "Low Battery" indicator

Survey Meter

Survey Meter


Operating Range:
mR/hr - .001 (1µR) to 100 mR/hr
µSv/hr - .01 to 1000
CPM - 0 to 300,000
CPS - 0 to 5000
Total/ Timer - 1 to 9,999,000 counts
Accuracy (Referenced to Cs-137):
mR/hr ± 15% from 0 to 30 mR/hr, ± 20% from 30 to 50 mR/hr
CPM ± 15% : 0 to 100,000 cpm, ± 20% from 100,000 to 300,000 cpm
Timer: Can set 1-minute sampling periods from 1 to 10 minutes
   10-minute sampling periods from 10 to 60 minutes
   1-hour sampling periods from 1 to 24 hours
Count Light: Red LED flashes with each radiation event
Audio Indicator: Internally mounted beeper (can be switched off for silent operation)
Anti-Saturation: Meter will hold at full scale in fields as high as 100 times the maximum reading
Power Requirements: (1) 9-volt alkaline battery
Temperature Range: 14°F to 122°F (-10°C to +50°C)
Battery Life: Typically 200 hours at normal background radiation levels
Dimensions: 5.9" h x 3.3" w x 1.2" d (15 x 8 x 3 cm)
Weight: 10.6 oz (300 grams) without battery

Sling Psycrometer

Sling Psycrometer


Psychrometer Sling
Untuk mengukur kelembaban udara dengan menggunakan 2 buah thermometer air raksa.
Specifications:
Batas pengukuran thermometer: -15 hingga +40°C
Skala thermometer: 0,2°C
Ukuran peralatan: 260 x 180 x 20 mm
Berat: 0,2 kg

Thermohygrometer

Thermohygrometer


Humidity :
Range, 10% to 95%
Resolution : 0.1%
Accuracy : ±3.5%
Infrared Temperature :
Range : -58°F to 932°F (-50°C to 500°C)
Resolution : 0.1°
Accuracy : ±2% or ±4°F (±2°C)
Air temperature :
Range : -4°F to 140°F (-20°C to 60°C)
Resolution : 0.1°
Accuracy : ±3°F/°C
Emissivity : 0.95
Field of view: 8:1
Dimensions: 5.9” x 2.95” x 1.57”.

Lux Meter

Lux Meter Measuring range:0-50000LUX 0-5000FC 3 RANGE: x1,x10,x100 resolution: 1 Accuracy: ±5%n HOLD Band pass filter Overload in...